Description
FoamPro Class A Foam: 1600/1601 Series (click here to see on FoamPro.com)
The FoamPro 1600 Class A Foam Series is available in two models, differing only in capacity.
Each system includes a Hypro twin plunger pump and DC (12 volt) motor assembly. Also included is a panel-mounted operator control unit with instructions, flowmeter , strainer, foam injection check valve, complete shielded cable set and RFI/EMI suppression kit.
The system features fully automatic foam proportioning, regardless of changes in flow or pressure, and delivers unmatched accuracy over the entire flow range. It proportions continuously, with no stopping to refill the foam tanks.
FoamPro Models 1600/1601 are capable of quickly pulling concentrate 3 feet allowing for increased mounting and installation flexibility.
Features:
- Discharge side injection
- No in-line restrictions
- Installs easily in new or existing apparatus
- Provides the smoothest proportioning available at ultra-low flows
- Delivers 0.1 to 1.7 gpm (.38 to 6.4 L/min) of concentrate
- Achieves full pump capacity with all known Class A concentrates
- 3 feet lift capability
- Optional:
- Remote Start/Stop for in-cab control
- Remote simulated flow switch
Control module features:
- Injection percentage from 0.1% to 1.0%
- On/Off control
- Foam percentage selector
- Low concentrate warning indicator
- Ultra-Bright LED light
- Advanced environmental protection
- Simulated flow - auto disengage
Ideal for use on:
- Brush rigs/Skid units
- Fast attack/wildland vehicles
- Municipal apparatus
- Compressed Air Foam Systems
1600 | 1601 | |||
Foam Pump: | Hypro Plunger Pump | Hypro Plunger Pump | ||
Foam Output: |
1.7 gpm @ 200 psi (6.4 L/min @ 13.8 BAR) |
1.0 gpm @ 200 psi (3.8 L/min @ 13.8 BAR) |
||
Pump Motor: |
1/3 hp (.25 kW) 12 & 24 volt DC | 1/3 hp (.25 kW) 12 & 24 volt DC | ||
Max Operating Pressure: |
400 psi (27.6 BAR) | 400 psi (27.6 BAR) | ||
Max Operating Temperature: |
160 degrees F (71 degrees C) | 160 degrees F (71 degrees C) | ||
Max Amp Draw: |
30 amps | 30 amps | ||
Amp Draw @ 200 psi (13.8 BAR): |
30 amps @ 12 volt DC 15 amps @ 24 volt DC |
19 amps @ 12 volt DC 11 amps @ 24 volt DC |
System Capacity:
Foam Concentration: |
1600 Max Water Flow GPM (L/min): | 1601 Max Water Flow GPM (L/min): | ||
0.2% | 850 GPM (3,218 LPM) | 500 GPM (1,893 LPM) | ||
0.5% | 340 GPM (1,287 LPM) | 200 GPM (757 LPM) | ||
1.0% | 170GPM (644 LPM) | 100 GPM (379 LPM) |
Attack Capability:
CLASS A Foam Concentration: |
1600 Max Coverage per Critical Application Rate (Iowa Formula): | 1601 Max Coverage per Critical Application Rate (Iowa Formula): | ||
0.2% | 85,000 cubic feet | 50,000 cubic feet | ||
0.5% | 34,000 cubic feet | 20,000 cubic feet | ||
1.0% | 17,000 cubic feet | 10,000 cubic feet |